URSUS® MT MIN SHD-GC 2 ÷ 25 kV

SHD-GC
Based on ICEA S-75-381, NEMA WC 58, CSA C22.2 No. 96
  1. PHASE CONDUCTORS
    MATERIAL: Bare flexible copper
    CONSTRUCTION: Class I acc. to ASTM B
    PHASE CONDUCTORS’ INSULATION: Ethylene-propylene rubber (EPR II) C 22.2 No. 96 and EPR Type II according to ICEA S-75-381
    OUTER SEMICONDUCTIVE RUBBER LAYER (not for 2kV and 5kV)
  2. PHASE CONDUCTORS’ SCREEN
    Tinned copper wire braid + textile fiber (Black - Blue - Red)
  3. GROUNDING CONDUCTORS
    MATERIAL: Bare flexible copper
    CONSTRUCTION: Class I acc. to ASTM B
  4. GROUND-CHECK CONDUCTOR
    MATERIAL: Bare flexible copper
    CONSTRUCTION: Class I acc. to ASTM B
    INSULATION MATERIAL: heavy duty special polyolefin
    INSULATION MATERIAL: heavy duty special polyolefin
    COLOUR: yellow
  5. INNER SHEATH
    MATERIAL: CPE compound tear and abrasion resistance, acc. to CSA C22.2 No. 96
  6. ANTITWISTING ELEMENT
    MATERIAL: polyester braid between inner and outer sheath
  7. OUTER SHEATH
    MATERIAL: CPE compound tear and abrasion resistance, acc. to CSA C22.2 No. 96
    COLOUR: black

APPLICATION

Flexible cable for energy supply of heavy mobile equipment such as drag lines, shovels, dredges, drills, under extreme mechanical stresses and abrasion during trailing operation in opencast mine.